The objective of ONC certification criterion 170.315(f)(6) is electronic transmission of Antimicrobial Use and Resistance (AUR) data to NHSN. Sentri7 will evaluate this objective using the following metrics for Sentri7 AUR customers who report AUR data to NHSN:
| Metric | Description |
| AR numerator submissions to NHSN | Annual counts of successful and failed AR numerator submissions to NHSN |
| AR denominator submissions to NHSN | Annual counts of successful and failed AR denominator submissions to NHSN |
| AU summary submissions to NHSN | Annual counts of successful and failed AU summary submissions to NHSN |
Each metric will provide annual counts that consider all eligible NHSN-defined locations and acute care settings as specified in the NHSN AUR protocol. Only the most recent attempt is considered for the report. Separate submissions may exist for each category (AU Summary, AR Denominator, AR Numerator) but only one submission (the latest attempt) for a given category and month will be eligible. Only uploads that are actually sent will be eligible - any errors that are caught before submission via Direct Send will make the submission ineligible for this reporting. We exclude failures due to customer configuration and only consider CDA file format and data-related errors.
It is expected that NHSN will accept all Sentri7 AUR submissions that comply with the AUR protocol in accordance with a facility’s monthly NHSN AUR reporting plan.
AUR reporting testing results
| Category | Total | % Accepted | % Failed |
| AU Summary Submissions to NHSN | 44401 | 93.98 | 6.02 |
| AR Numerator Submissions to NHSN | 339609 | 95.61 | 4.39 |
| AR Denominator Submissions to NHSN | 10014 | 95.75 | 4.25 |
| Total | 394024 | 95.43 | 4.57 |